Vertex Group is among top group of firms to be listed among the best advanced 11KVHT Panel Manufacturers, Suppliers and Exporters from Noida, Uttar Pradesh, India. We are proud to be the System Integrator of Siemens for HT Panels. We manufacture 11 KV VCB/ HT Power Panels at our In-house manufacturing unit in Greater Noida with all the latest tools & technologies like laser-cutting machine, NC Shearing and Sheet Bending Machine, Power Press, Lathe Machine, Grinding Machine, Surface Machine, Powder Coating, Oven, 9-tank process etc. Vertex Group has well-experienced engineering design team that works with the latest software tools to produce optimum design solutions.
Produced using best grade materials and excellent electrical components, our High Tension Panel exhibit great strength and rigid panel structure which is anti-corrosive and have weather resistive properties. We also subject our HT Control Panel for accepted quality and performance standards. Only after they pass the checks, our HT VCB Panels are delivered to end users.
👉 Fully type tested including internal arc fault test.
👉 Belongs to 8BK8 series with all safety features.
👉 Single ICOG ( Indoor/ Outdoor).
👉 Multi Panel-> Indoor/Outdoor.
👉 630Amp to 2000 Amp.
👉 Short Circuit 18KA to 40KA.
👉 IAC- 0.1 sec & 1 sec
👉 IEC 62271-100
👉 IEC 62271-200
👉 IS 3427 and IS 12729.
👉 No separate maintenance trolley required.
👉 Safe and easy truck movement behind closed cubicle door.
👉 Separately padlockable shutter for bus and cable side fixed contacts.
👉 Automatic dropping ramp for facilitating truck removal.
👉 Single busbar air insulated metal-clad switchgear.
👉 Circuit breaker mounted on withdrawable truck.
👉 Simple and rugged shutter mechanism.
👉 Encapsulated feeder connections.
👉 All switching operations performed with breaker compartment door closed.
👉 Earthed metallic partitions and shutters prevent contact with live parts.
👉 Individual high voltage compartment tested for Internal arc fault.
👉 Full metallic enclosure ensures high resistance to ingress and interference under all operating conditions.
Technical Data: | |
---|---|
Rated voltage | 12kV |
Rated frequency | 50 Hz |
Rated short-duration power-frequency withstand voltage | 28 kV* |
Rated lighting impulse withstand voltage | 75 kV |
Rated short-time withstand current,3 s | 26.3 kA |
Rated peak withstand current at 50 Hz | 66 kAp |
Rated short-circuit breaking current | 26.3 kA |
Rated short-circuit making current at 50 Hz | 66 kAp |
Rated normal current of busbar | 2000 A |
Rated normal current of feeders-with circuit-breaker | 1450 A |